-40%

215' 10 AWG THHN/THWN-2 Stranded Bld Wire-drops from solar project big discount

$ 34.05

Availability: 37 in stock
  • Condition: New
  • Material: Copper
  • Brand: Alan Wire
  • Color: Black
  • Contact Material: Copper
  • Country/Region of Manufacture: United States

    Description

    Drop from solar project. 215
    ' wire for your project.
    Wire is in new condition but may have small nicks in nylon outer jacket (not the PVC coating)
    Don't overpay at the big box or buy an entire spool you don't need.  priced {{detail_product_description}}.30/foot
    THHN/THWN-2 Stranded Building Wire.
    Applications:
    Type THHN/THWN-2 building wire is intended for general purpose applications as defined by the National Electrical Code (NEC). Type THHN-THWN-2 is permitted for new construction or rewiring for 600-volt applications. Applications requiring Type THHN or THWN-2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.
    Also Known As:
    10 Gauge Copper Wire, #10 AWG THWN, building wire, 10 gauge hook up wire, conduit wire, bathtub wire, lighting wire, nylon copper wire, construction cable, 10 gauge wire, #10 awg wire, 100' of 10 AWG Wire
    Features:
    Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.
    Jacket:
    A tough, polyamide, Nylon outer covering per UL-1063 and UL-83.
    Standards:
    Underwriters Laboratories Standards UL-83, UL-1063, UL-758
    AWM Spec 1316, 1317, 1318, 1319, 1320, 1321
    ASTM Stranding Class B3, B8, B787
    Federal Specification A-A-59544
    Canadian Standards Association C22.2 No. 75
    NEMA WC70/ICEA S-95-658
    Institute of Electrical and Electronics Engineers
    Construction:
    Conductors:
    Solid, uncoated copper conductors per ASTM-B3
    Stranded, uncoated copper conductors per ASTM-B3, ASTM-B787 and ASTM-B8
    Insulation:
    Color-coded Polyvinyl Chloride (PVC), heat and moisture-resistant, flame-retardant compound per UL-1063 and UL-8
    Specifications*:
    Size:
    10 AWG
    Number of Strands:
    19
    Cross Section Area (mm2):
    5.26
    PVC Insulation Thickness (Conductor):
    0.510 mm / 0.020 inches
    Nylon Jacket Thickness:
    0.100 mm / 0.004 inches
    Outside Diameter:
    4.07 mm / 0.160 inches
    Allowable Ampacity:
    30 Amps at 60ºC / 30 Amps at 75ºC / 30 Amps at 90ºC